Best Price in Dhaka Bangladesh
The MAG 900 (and its close variant MAG 910) is a full-bore inductive (magnetic) flowmeter tailored for measuring flow and totalized volume of conductive liquids, including dirty fluids with solids, slurries, and water treatment applications. It supports bidirectional flow measurement .
Fluid Conductivity: ≥5 µS/cm (≥20 µS/cm for demineralized water)
Flow Velocity Range: 0.1 – 10 m/s;
Accuracy: ±0.5% for 0.5–10 m/s; ±1.0% for 0.1–0.5 m/s
Nominal Pipe Sizes: DN 10 to DN 1000 (approx. 10 mm to 800 mm or larger); flange connection per DIN/ANSI standards
Pressure & Temperature:
Standard: up to PN 10/16 (10–16 bar), media temp up to 70 °C (hard-rubber liner) or up to 130 °C with PTFE liner (remote electronics version)
Hygienic/wafer versions rated to 150 °C / 16 bar
Outputs & I/O:
Frequency (up to 12 kHz) and pulse outputs (up to 50 Hz), configurable;
Analog 4–20 mA (active/passive), relay outputs (up to 100 V/0.5 A), one isolated digital input; RS‑232 and RS‑485 communications support flow data and configuration
Display & Electronics: Built-in alphanumeric LCD shows flow rate, volume (positive, negative, total), supports low-flow correction and configurable sensitivity bandwidth; non-volatile backup memory for configuration data
Construction & Environmental Ratings:
Electronics housing: IP65 / NEMA 4; Sensor: IP67 or IP68 depending on construction
Body materials: stainless steel tube, PTFE or rubber lining; electrodes of SS, Hastelloy, tantalum options
| Feature | Details |
|---|---|
| Flow Range | 0.1–10 m/s (~Q velocity) |
| Accuracy | ±1% (<0.5 m/s), ±0.5% above 0.5 m/s |
| Pipe Sizes | DN 10 to DN 1000 (up to 800 mm+) |
| Media Compatibility | Conductive liquids, dirty fluid with solids |
| Output Types | Frequency (<12 kHz), Pulse (<50 Hz), 4–20 mA, Relay, RS-232, RS-485 |
| Temp & Pressure | Up to 130 °C with PTFE liner; PN 16 standard |
| Protection Ratings | Electronics IP65/NEMA 4, Sensor IP67–68 |
Login Or Registerto submit your questions to seller
No none asked to seller yet